[. . . ] 158TS10960
7/27/04
3:56 PM
Page 1
MODEL: T175
ONE NO - ONE NC CONTACTS
LR3730
24 HR DIAL TIME SWITCH WITH "SKIPPER®"
MAY BE WIRED AS SINGLE POLE DOUBLE THROW
40 AMP. [. . . ] REPLACE INSULATOR BEFORE TURNING ON ELECTRICITY.
MINIMUM COPPER WIRE SIZE (AWG) MAX. 240 V.
PRESSURE PLATE TERMINAL SCREW MAKE SURE WIRE INSULATION CLEARS PRESSURE PLATE
14 12 10 8
15 20 30 40
60 60 60 75
1/2 1 2 -
2 2 1/2 3 5
N/A
N/A
PROGRAMMING INSTRUCTIONS 1. TO SET "ON" AND "OFF" TIMES: Hold trippers against edge of CLOCK-DIAL, pointing to time (AM or PM) when ON and OFF operations are desired, tighten tripper screws firmly. Turn in either direction and align the exact time-of-day on the CLOCK-DIAL (the time now, when switch is being put into operation) to the pointer. TO SKIP OPERATION(S) ON SELECTED DAY(S): Insert SKIPPING SCREW(S) in SKIPPER WHEEL for day(s) automatic operation(s) is/are NOT required. Move MANUAL LEVER to "OFF" and rotate SKIPPER WHEEL to locate correct day-of-week opposite DAY ARROW--"YESTERDAY" if ON/CUTOUT TRIPPER has not yet advanced wheel "TODAY" if it has. [. . . ] INTERMATIC INCORPORATED
SPRING GROVE, ILLINOIS 60081-9698
158TS10960 [. . . ]